Skip to main content

IPS Group States

BluSKY URL:https://blusky.blub0x.com/en-US/MercuryIPSGroup

Overview

An Intrusion Prevention System(IPS) Group is used to organize individual IPS Points into an easily managed group. This article provides a resources for understanding the different states of the IPS Group.

An IPS Group will be in one of the following states:

IPS Group StateDescription
DisarmedNeither  an interior nor an exterior point will cause an alarm if it is activated. The IPS group may be armed only if none of the perimeter points are active.
FaultThe system is disarmed and points are in supervisory fault or offline.
Armed AwayAll points will cause an alarm after the exit or entry delays expire
Armed StayOnly the Perimeter points will cause an alarm if activated.
Armed InstantPerimeter points will cause an alarm if activated. Interior points will not cause an alarm if activated.
Entry DelayThe system was armed and a point for which the entry delay parameter is set has been activated.
Exit DelayThe system has been armed and an exit delay is in progress.
AlarmThe system is in alarm and the alarm has not been canceled.
Alarm CanceledThe system has an active alarm, the alarm has been silenced and alarm history is available.