Person Reader Recognition Distance Settings Guidance
Here’s a structured guideline for Person Reader recognition distance settings based on geometry and use case:
General Principles
- Recognition distance must balance early pipeline start (for speed and responsiveness) with false detection control (avoiding passersby being picked up).
- Off-angle geometry widens the effective recognition distance (Pythagorean rule applies).
- Faster approaches (e.g., lobby turnstiles) require longer initial detection range to compensate for motion blur and lower confidence scores.
- Always tune recognition distances with site geometry, approach speed, and user intent in mind.
Recommended Settings by Environment
1. Turnstiles in Lobby Areas
-
Typical Approach: Fast walking, often at an angle, corridors turning into banks.
-
Challenges: Motion blur, angled entry, crowds walking past nearby.
-
Recommendation:
-
Start recognition at ~6 feet.
-
Longer distance helps pipeline engage earlier.
-
If false detections from side-passers occur, reduce slightly (5-5.5 feet).
-
Prioritize confidence accumulation over instant recognition.
2. Elevator Lobbies (Upper Floors)
-
Typical Approach: Slower, more deliberate; smaller throats, less crowding.
-
Challenges: Less room behind PR, but users have time to align.
-
Recommendation:
-
Recognition at 4-5 feet is optimal.
-
Crowding less likely, so false detect risk is lower.
-
If angle approaches are common (PRs in throats), extend to ~5.5 feet to account for off-angle pickup.
3. Main Lobby without Turnstiles (e.g., 50 California)
-
Typical Approach: Angled walk-up; PRs often in throats.
-
Challenges: 60° off-angle approach means geometric distance > straight-line distance.
-
Recommendation:
-
Effective detection should feel like 5 feet straight-line, even if geometric distance is larger.
-
Allow wider FOV pickup so the system feels responsive.
-
Avoid forcing users to square up directly in front.
4. Doors / Intercom Applications
-
Typical Approach: Intentional walk-up, usually straight on.
-
Challenges: Passersby glancing at device can trigger false detects.
-
Recommendation:
-
Recognition distance of ~4 feet works well.
-
If geometry allows and false detect risk is low, extend to 5 feet for faster response.
-
Prioritize intent over range-better to require a slight step forward than to constantly mis-trigger.
Key Takeaways
- Lobby turnstiles: 6 ft (tune down if false detects).
- Elevator lobbies (upper floors): 4-5 ft, extend to 5.5 ft for angle approaches.
- Lobby without turnstiles: ~5 ft equivalent, adjusted for off-angle.
- Doors/intercoms: 4-5 ft, tuned for intent.